Gas Regulators
Categories
-
N5 OPD
Read morePipe Size: 3/8″ to 2″
Outlet Pressure Range: 7″ to 14″ wc
The NMT® N5 OPD (Overpressure Protection Device) Series gas regulator is an ANSI Z21.80 certified self-operating OPD two-stage regulator with vent limiting for use in residential, commercial, and industrial applications. The OPD function allows for installation in applications where pressures must be limited to 2psig per ANSI Z21.80. The standard vent limiting feature allows for indoor use without the need to pipe external vent lines while still maintaining OPD protection.
Features
- ANSI Z21.80 certified
- Vent limiter STANDARD (No need to install vent pipe!)
- Multi-position installation
- Extended corrosion resistance
- Up to 10 psig operating pressure
Specifications
- Maximum inlet pressure: 10 psig
- Maximum Emergency Inlet Exposure Pressure: 85 psig (inlet side only)
- Ambient Temperature Range: -40°F to +212°F
- Gas Type: Natural gas, LPG, air, other non-corrosive gas
- Options: Vent cap, vent elbow
Literature & Resources
-
N5 Series
Read moreN5
Pipe Size: 3/8″ to 2″
Outlet Pressure Range: 7″ to 1.5 psig
The NMT® N5 Series gas regulator is an ANSI Z21.80 certified self-operating regulator with a vent limiting option for use in residential, commercial, and industrial applications. The N5 vent allows for indoor use without the need to pipe external vent lines. With the added benefit of extended corrosion resistance, the N5 allows for various applications where the best regulation performance is required.
Features
- ANSI Z21.80 certified
- Vent limiter option (No need to install vent pipe)
- Multi-position installation
- Extended corrosion resistance
- Up to 15 psig operating pressure
Specifications
- Gas types: Natural gas, LPG, air, other dry non corrosive gases
- Maximum inlet pressure: 2 psig; 15 psig max
- Maximum inlet pressure w/ vent limiter: 2 psig; 10 psig max
- Maximum emergency inlet pressure: 85 psig
Literature & Resources
-
NGR02
Read morePipe Size: 1/2″ to 1-1/4″
Outlet Pressure Range: 2″ to 5 psig
The NMT® NGR02 series spring-loaded gas regulators with internal relief provide consistent and controlled pressure in a variety of residential, industrial, and commercial applications. The NGR02 meets ANSI Z21.80 for Class I, Class II, Vent Limiting, and OPD (Overpressure Protection Device) applications and is designed to be used in many applications where non-corrosive dry gases are used.
Features
- ANSI Z21.80 certified
- Vent Limiter Option
- Internal Relief – OPD
- Outlet pressures up to 5 psig
- Conforms to ANSI B109.4
- Corrosion-resistant exterior
Specifications
- Gas types: Natural gas, LPG, other non corrosive dry gases
- Maximum inlet pressure: 10 to 125 psig per orifice
- Maximum emergency inlet pressure: 175 psig
- Operating temperature: -40°F to +140°F
Literature & Resources
-
NGR04
Read morePipe Size: 1-1/4″ to 3″ FL
Outlet Pressure Range: 3″ to 3 psig
The NMT® NGR04 series spring-loaded gas regulators with internal relief provide consistent and controlled pressure in a variety of residential, industrial, and commercial applications. The NGR04 meets ANSI Z21.80 for Class I, Class II, Vent Limiting, and OPD (Overpressure Protection Device) applications and is designed to be used in many applications where non-corrosive dry gases are used.
Features
- ANSI Z21.80 certified
- Vent Limiter Option
- Internal Relief – OPD
- Outlet pressures up to 3 psig
- Conforms to ANSI B109.4
- Corrosion-resistant exterior
Specifications
- Gas types: Natural gas, LPG, other non corrosive dry gases
- Maximum inlet pressure: 10 to 125 psig per orific
- Maximum emergency inlet pressure: 175 psig
- Operating temperature: -40°F to +140°F
Literature & Resources
-
NGR06
Read morePipe Size: 1-1/4″ to 3″ FL
Outlet Pressure Range: 2″ to 7 psig
The NMT® NGR06 series spring-loaded gas regulators with internal relief provide consistent and controlled pressure in a variety of residential, industrial, and commercial applications. The NGR06 meets ANSI Z21.80 for Class I, Class II, Vent Limiting, and OPD (Overpressure Protection Device) applications and is designed to be used in many applications where non-corrosive dry gases are used.
Features
- ANSI Z21.80 certified
- Vent Limiter Option
- Internal Relief – OPD
- Outlet pressures up to 7 psig
- Conforms to ANSI B109.4
- Corrosion-resistant exterior
Specifications
- Gas types: Natural gas, LPG, other non corrosive dry gases
- Maximum inlet pressure: 25 to 125 psig per orifice
- Maximum emergency inlet pressure: 175 psig
- Operating temperature: -40°F to +140°F
Literature & Resources
-
NGR08
Read morePipe Size: 1-1/4″ to 3″ FL
Outlet Pressure Range: 2″ to 7 psig
The NMT® NGR08 series spring-loaded gas regulators with internal relief provide consistent and controlled pressure in various residential, industrial, and commercial applications. The NGR08 meets ANSI Z21.80 for Class I, Class II, Vent Limiting, and OPD (Overpressure Protection Device) applications and is designed for use in many applications where non-corrosive dry gases are used.
Features
- ANSI Z21.80 certified
- Vent Limiter Option
- Internal Relief – OPD
- Outlet pressures up to 7 psig
- Conforms to ANSI B109.4
- Corrosion-resistant exterior
Specifications
- Pipe size: 1-1/4″ NPT to 3″ FL
- Gas types: Natural gas, LPG, other non corrosive dry gases
- Maximum inlet pressure: 25 to 125 psig per orifice
- Maximum emergency inlet pressure: 175 psig
- Operating temperature: -40°F to +140°F
Literature & Resources
-
NGRB Series
Read moreNGRB
Pipe Size: 2″ and 3″ FL
Outlet Pressure Range: 7″ to 21.4 psig
The NMT® NGRB Series regulators are single stage, self-operated regulators for heavy duty work under high, medium and low-pressure applications, for all types of non-corrosive gases. The NGRB Series regulator has a built-in partial relief valve (token relief), which allows occasional rises in the outlet pressure above the relief pressure to be released gradually into the atmosphere without triggering an overpressure shut-off valve or high limit switch due to occurrences such as sudden variations in flow or variations in temperature causing an increase in downstream pressure.
NOTE: The NGRB regulator requires a downstream sensing line that senses the downstream pressure to operate. This sensing line must be installed within the piping system and connected to the regulator at its appropriate connection.
Features
- Internal token relief
- Corrosion-resistant exterior
- High capacity at low inlet pressures
- Internal balanced valve allowing low lock up with high inlet pressures
- Field-interchangeable springs
- Designed for easy maintenance
Specifications
- Gas types: Natural gas, LPG, other non corrosive dry gases
- Maximum inlet pressure: 145 psig
- Maximum emergency inlet pressure: 145 psig
- Operating temperature: -4°F to +140°F
Literature & Resources